TurbinePayback

Wind Turbine Payback in Wilcox County, AL

Wind turbine payback in Wilcox County

No. The turbine wears out before it pays for itself.

At 30 m, the height a home turbine tower usually reaches, the wind in Wilcox County, AL averages 2.94 m/s (6.6 mph). A 10 kW turbine there would make about 2,427 kWh a year, worth $401 at AL's 16.51¢/kWh. Against an installed cost of about $100,000, that is a payback of over 100 years, and the turbine is built to last about 20.

What to do in Wilcox County

A home turbine is not worth buying for savings in Wilcox County unless your spot is far windier than the county average, 7.5 m/s at the hub against 2.94 m/s here. Per kW, solar panels would make about 1,364 kWh a year here against the turbine's 243, so get a solar quote first.

What would have to change

Against the rest of AL

Wilcox County is the 3,095th windiest of 3,144 US counties at turbine height; the national middle is 4.79 m/s. The windiest in AL is Mobile County at 4.72 m/s, payback 57 years.

Month by month in Wilcox County

March is the strongest month here, at 3.34 m/s and about 315 kWh. July is the weakest, 2.30 m/s and 82 kWh, so the best month makes 3.8 times the worst. November to March brings in 55% of the year's output in Wilcox County.

MonthWind at 30 mOutputWorth
January3.23 m/s282 kWh$47
February3.30 m/s276 kWh$46
March3.34 m/s315 kWh$52
April3.30 m/s293 kWh$48
May2.87 m/s189 kWh$31
June2.46 m/s105 kWh$17
July2.30 m/s82 kWh$14
August2.36 m/s92 kWh$15
September2.74 m/s156 kWh$26
October3.01 m/s223 kWh$37
November3.17 m/s258 kWh$43
December3.16 m/s264 kWh$44

What a taller tower would buy

Measured at 10 m the wind in Wilcox County averages 1.72 m/s; at 50 m it is 3.77 m/s. That gives a shear exponent of 0.488, typical of rough, sheltered ground: trees or buildings slow the low wind a lot. Going from 20 m to 50 m takes output from 1,173 to 5,477 kWh a year, 367% more, before counting the extra cost of the taller tower. Why tower height decides it explains the shear behind these numbers.

Hub heightAverage windOutputPayback
20 m2.41 m/s1,173 kWhover 100 years
30 m2.94 m/s2,422 kWhover 100 years
40 m3.38 m/s3,871 kWhover 100 years
50 m3.77 m/s5,477 kWhover 100 years

Counties around Wilcox County

4 of the 6 closest counties are windier at turbine height; the windiest, Dallas County, averages 3.35 m/s.

Sun versus wind in Wilcox County

Wilcox County gets 4.67 kWh of sunshine per square metre a day on average. One kW of solar panels here would make roughly 1,364 kWh a year; one kW of the turbine above makes 243. Kilowatt for kilowatt, panels make 5.6 times as much here as the turbine. Panel output assumes an 80% system performance ratio. Wind or solar runs the same comparison for every county.

How this is worked out

Wind is NASA's Power climate record, the 2001-2025 average at 10 m and 50 m for the county's centre, carried to 30 m with this county's own measured wind shear and spread into hours with a Rayleigh distribution. The turbine is a generic 10 kW, 7 m rotor machine with 10% losses. Cost is $10,000 per kW installed with no tax credit, because the federal one ended in 2025. One county-centre number cannot see your hilltop or your tree line, so treat it as the starting point for a site survey, not a substitute. The full method and its weak spots are in how the numbers are made.