No. The turbine wears out before it pays for itself.

At 30 m, the height a home turbine tower usually reaches, the wind in Capitol Planning Region, CT averages 3.52 m/s (7.9 mph). A 10 kW turbine there would make about 4,408 kWh a year, worth $1,211 at CT's 27.47¢/kWh. Against an installed cost of about $100,000, that is a payback of 83 years, and the turbine is built to last about 20.

What to do in Capitol Planning Region

A home turbine is not worth buying for savings in Capitol Planning Region unless your spot is far windier than the county average, 5.8 m/s at the hub against 3.52 m/s here. Per kW, solar panels would make about 1,142 kWh a year here against the turbine's 441, so get a solar quote first.

What would have to change

Against the rest of CT

Capitol Planning Region is the 2,490th windiest of 3,144 US counties at turbine height; the national middle is 4.79 m/s. The windiest in CT is Greater Bridgeport Planning Region at 5.26 m/s, payback 25 years.

Month by month in Capitol Planning Region

March is the strongest month here, at 4.19 m/s and about 643 kWh. August is the weakest, 2.83 m/s and 181 kWh, so the best month makes 3.6 times the worst. November to March brings in 59% of the year's output in Capitol Planning Region.

MonthWind at 30 mOutputWorth
January4.08 m/s593 kWh$163
February4.25 m/s608 kWh$167
March4.19 m/s643 kWh$177
April3.83 m/s471 kWh$129
May3.24 m/s286 kWh$79
June2.94 m/s199 kWh$55
July2.84 m/s183 kWh$50
August2.83 m/s181 kWh$50
September3.06 m/s228 kWh$63
October3.49 m/s365 kWh$100
November3.66 m/s410 kWh$113
December3.86 m/s500 kWh$137

What a taller tower would buy

Measured at 10 m the wind in Capitol Planning Region averages 2.14 m/s; at 50 m it is 4.43 m/s. That gives a shear exponent of 0.452, typical of rough, sheltered ground: trees or buildings slow the low wind a lot. Going from 20 m to 50 m takes output from 2,392 to 8,924 kWh a year, 273% more, before counting the extra cost of the taller tower. Why tower height decides it explains the shear behind these numbers.

Hub heightAverage windOutputPayback
20 m2.93 m/s2,392 kWhover 100 years
30 m3.52 m/s4,395 kWh83 years
40 m4 m/s6,602 kWh55 years
50 m4.43 m/s8,924 kWh41 years

Counties around Capitol Planning Region

5 of the 6 closest counties are windier at turbine height; the windiest, Southeastern Connecticut Planning Region, averages 4.21 m/s.

Sun versus wind in Capitol Planning Region

Capitol Planning Region gets 3.91 kWh of sunshine per square metre a day on average. One kW of solar panels here would make roughly 1,142 kWh a year; one kW of the turbine above makes 441. Kilowatt for kilowatt, panels make 2.6 times as much here as the turbine. Panel output assumes an 80% system performance ratio. Wind or solar runs the same comparison for every county.

How this is worked out

Wind is NASA's Power climate record, the 2001-2025 average at 10 m and 50 m for the county's centre, carried to 30 m with this county's own measured wind shear and spread into hours with a Rayleigh distribution. The turbine is a generic 10 kW, 7 m rotor machine with 10% losses. Cost is $10,000 per kW installed with no tax credit, because the federal one ended in 2025. One county-centre number cannot see your hilltop or your tree line, so treat it as the starting point for a site survey, not a substitute. The full method and its weak spots are in how the numbers are made.